Spectrophotometer

UV-VIS Spectrophotometer

SP-3000SB


  • Single Beam Type
  • Photometric, Spectrum, Kinetics, Quantitation
  • 7 Inch Color LCD with Touch Screen
  • 8-position Multi-cell Holder
  • Voice Guidance
  • OptiView PC Software (Option)

SP-3000SB
UV-VIS SPECTROPHOTOMETER

Experience the fast and convenient SP-3000SB.

The simple and affective design fits well into any space.

OPTIVIEW (PC Software)

OPTIVIEW is a software that allows you to remotely control

SP-3000SB to collect and analyze data. (Provided separately)

Secure (PC Software)

Secure is a management program that can track and audit all

actions performed in OPTIVIEW. (Provided separately)

Core functions:

Login

- Access restriction based on authentication target and method

- Group-specific authorization and function restriction

Electronic signature

- Authentication and non-repudiation through level-specific signature Audit trail

- Audit records based on user actions.

OPTIMA Spectrometer Family


Multi-cell measurement

Microvolume measurement

Cuvette measurement

Wavelength range

Feature

SP-3000SB

O
X
O
190 to 1100 nm
Single-beam

SP-3000DB

O
X
O
190 to 1100 nm
Double-beam

NanoEX Plus

X
O
O
190 to 850 nm
Xenon flash lamp
NanoEX Lite
X
O
O

Pedestal: 260, 280 nm

Cuvette: 600 nm

LEDs
After Sales Service Policy

At OPTIMA Inc., we provide systematic services based on professional

expertise to meet the diverse needs of our customers.


Free Warranty Service

We offer free repair and replacement services for products (excluding consumables)

within one year of purchase and for lamp failures that occur within the warranty

period. We strive to deliver stable performance through our structured and

continuous services and extensive experience.

THE BEST VISUAL

AND FUNCTIONAL EXPERIENCE

SP-3000SB focuses on user convenience and has an intuitive interface that allows for accurate measurement and analysis of data with a single touch. It also includes a variety of functions optimized for experimental equipment, and measurement results can be easily edited and exported.

PC-Link

You can change the device mode to remote mode and

use it in conjunction with a PC via OPTIVIEW.

Self-test (Built-in test, BIT) feature

When you turn on your device, it performs a self-diagnostic to determine if there is any abnormality. During the initial self-diagnosis, it will check the connection status, operation of each motor, lamp, and calibration status to determine if there is anything wrong with the device. It will check each item and display the results to maintain the best condition always.


*BIT Checklist: Link, Wave Motor, Cell Motor, Filter Motor, W Lamp, D2 Lamp, D2 Lamp (Peak)

Remote Control Mode

SP-3000SB can perform measurements directly as a standalone device, but it can also be controlled remotely by connecting to a PC. In a network environment, data can be measured and analyzed on a PC without workspace restrictions.

Touch-type graph function

The measurement results are appropriately auto-scaled and presented in the form of a table or graph. The pinch zoom function allows you to easily zoom in on a desired part of the graph as needed.

Convenient data management

You can save measurement conditions and data in the built-in memory (32GB provided as standard) or external USB flash drive to perform various tasks such as data conversion through OPTIVIEW, application of conversion formulas, and exporting to Excel.

Photometric Mode

  • This mode allows you to easily measure absorbance (Abs) (or transmittance (%T)) at a specific wavelength.
  • You can set the factor (K) value, so you can perform a simple quantitative analysis of a sample with a known extinction coefficient.
  • Measurements can be made at up to 20 wavelengths at a time.
  • Automatic analysis of up to 8 samples is possible using the multi-cell holder.

Quantitation Mode

  • This is a mode for quantitative analysis using a standard curve.
  • You can perform quantitative analysis of the sample of interest using a standard curve created with a given formula or concentration-absorbance pairs of standard samples.
  • An accurate result can be obtained with multiple determinations of up to 8 iterations.

Standard Curve Generation Mode

The mode for creating a standard curve provides four fitting options:

Linear (Zero-crossing), Linear, Quadratic, and Cubic.


You can create a standard curve by measuring standard samples of various concentrations or directly entering known absorbance for each concentration.


You can modify existing standard curve data through the import function.

Spectrum Mode

  • This mode allows the user to check the spectrum of the desired wavelength band.
  • Measurement data can be switched between absorbance (Abs) and transmittance (%T).
  • Automatic spectrum analysis of up to 8 samples is possible.
  • Supports pinch-zoom and peak/valley locator functions

Kinetics Mode

  • This mode allows you to check the change in  absorbance (or transmittance) over time at a specific  wavelength.
  • Measurements are taken at regular intervals. The minimum interval is 1 second.
  • The progress is displayed during measurement, and measurement is possible for up to 99 hours.
  • The absorbance change of up to 8 samples can be acquired automatically.
    * The minimum measurement time interval is adjusted depending on the measurement conditions.

Report & Print

Users are provided with the ability to check, save (PDF/HTML), and print measured data in report format. This feature supports systematic reporting and documentation of experimental results and plays an important role in maximizing the usability and accessibility of data.

These documentation and storage functions increase the reproducibility and transparency of research and ensure reliable data management.

THE UNCOMPROMISI

PERFORMANCE

SP-3000SB products undergo rigorous quality testing prior to shipment to ensure proven performance.

Wavelength accuracy & repeatability


SP-3000SB adopts its own high-resolution wavelength measurement mechanism

to ensure wavelength reproducibility of less than 0.1 nm across the entire band.

The wavelength accuracy verified through a Holmium Oxide filter (MU* = ±0.2 nm) is ±0.5 nm, and the repeatability is less than ±0.1 nm.

Certified Value
279.44 nm
360.89 nm
453.67 nm
536.52 nm
638.00 nm
Measured (Mean)
279.49 nm
361.00 nm
453.80 nm
536.80 nm
638.00 nm
Measured (Std)
±0.00 nm
±0.00 nm
±0.00 nm
±0.00 nm
±0.00 nm

(*) MU : Measurement Uncertainty

SP-3000SB automatically verifies wavelength accuracy using the Balmer lines of the D2 lamp at boot time.

Using the validation mode, you can also check the spectral bandwidth (SBW) of the device.

Certified Value
486.0 nm
656.1 nm
Measured (Mean)
486.0 nm
656.0 nm
Measured (Std)
±0.00 nm
±0.00 nm
Spectral Bandwidth
< 1.8 nm
Measured
1.2 nm

Baseline stability

Since SP-3000SB uses a tungsten lamp as the light source, the measured values may fluctuate due to the light source drift phenomenon immediately after turning on the equipment. This phenomenon gradually stabilizes through the light source warm-up process. Therefore, for high-precision measurements, warm-up for about an hour or more is recommended. After warm-up, stability within 0.001 Abs/h is guaranteed.

Photometric accuracy & repeatability

SP-3000SB can minimize signal fluctuations over time by automatically updating the blank signal for each measurement without additional manipulation utilizing the multi-cell holder.

Precise signal processing provides excellent noise characteristics, ensuring photometric accuracy within ±5 mAbs or 1%, and photometric repeatability within ±3 mAbs.

All products are verified using SRM 935a (MU ≅ ±5 mAbs) and SRM 930e (MU ≅ ±3 mAbs) before shipment.

Measurement results of SRM 935a + 0.001 M perchloric acid solution (60 mg/l)

Wavelength
235.0 nm
257.0 nm
313.0 nm
350.0 nm
Certified Value
0.7472
0.8637
0.2935
0.6411
Measured (Mean)
0.740
0.856
0.292
0.641
Measured (Std)
0.000
0.000
0.000
0.000

Measurement results of SRM 930e

Wavelength
440.0 nm
465.0 nm
546.1 nm
590.0 nm
635.0 nm
Certified Value
1.0218
0.9610
0.9983
1.0938
1.0738
Measured (Mean)
1.022
0.961
0.998
1.094
1.074
Measured (Std)
0.000
0.000
0.000
0.000
0.000

Baseline Flatness

SP-3000SB automatically corrects the baseline for each measurement, providing

consistent baseline flatness (< 0.001 Abs RMS) without the need for separate

baseline correction.


PC Software

OPTIVIEW (Optional)

OPTIVIEW is a Windows-based PC software that can be used to remotely operate OPTIMA’s spectrophotometers using a PC to acquire, manage, and analyze the data. It provides a continuous user experience through the familiar screen and intuitive interface of SP-3000SB.


OPTIVIEW allows you to perform measurements with a single click and check the progress of the experiment through real-time measurement data and cell holder positions displayed on the screen. It also provides a folder-based task management function for data management. Customizable layouts - docking and split pinning - and ribbon menus that support quick analysis through associative placement provide a convenient working environment.

Multiple output formats

You can easily output measured data and analysis results in a variety of formats. You can save them in OPTIVIEW’s own format for further analysis, or collect only the necessary data and output them in a report

format.


The supported output formats are as follows:

Image format (.png)

Text format (.txt)

Excel format (.csv, .xlsx)

Report format (.pdf)

Native format (.ova*)

ACCESSORIES

Compatibility with various accessories provides the perfect solution for each laboratory and experimental environment.

Multi Cell Holder (Standard)

The multi cell holder to be able to measure automatically up to 8 samples.

Micro Volume Cell Holder

The single cell holder available, in case that sample’s volume is below 500㎕.


Optical Path Length: 10 mm

Center Height: 15 mm

Round Cell Holder

The single cell holder available, when using circle cell to analyze a sample.


Test Tube Diameter: 16 mm / 25 mm

Test Tube Height: max. 100 mm

Long Path Cell Holder

The single cell holder is used, when measuring after lengthening a light path in order to analyze a low density sample.


Optical Path Length: 20 - 100 mm

Temperature Cell Holder (Water/Oil Circulator Type)

This is used to control the temperature of the cell holder by using a temperature circulatory device.


Tubing Size: 6 mm

Film Cell Holder

The single cell holder available for measuring the solid sample for a light to pass through such as an optical film or a slide glass.


Sample Size: max. 100 mm(H) x 70 mm(W)

Sample Thickness: max. 5 mm

Sipper

It is possible to perform automatic suction and measurement of liquid samples, and it has a built-in function to automatically correct the amount of suction, enabling accurate and stable sample processing.


Flow rate range: 0.035~570

Speed range: 0.5~150 rpm

Speed resolution: 0.1 rpm (0~100 rpm), 1 rpm (100~600 rpm)

SP-3000SB SPECIFICATIONS

Photometrics System

Single-beam type

Light Source(s)

Tungsten Halogen Lamp & Deuterium Lamp (Built-in light source auto interchanging motor)

Detector

Silicon Photodiode

Spectral Bandwidth

< 1.8 nm

Wavelength Range

190 to 1100 nm

Wavelength Display (setting)

 0.1 nm

Wavelength Accuracy

<± 0.5 nm

Wavelength Repeatability

<± 0.1 nm

Slew Rate

7,800 nm/min

Scanning Speed

4,000 nm/min

Photometric Range

Absorbance: -3 A to 3 A/Transmittance: 0% to 300%

Photometric Accuracy

<± 0.003 Abs at 0.5 Abs

<+ 0.005 Abs at 1.0 Abs.

Photometric Repeatability

<+ 0.003 Abs

Baseline Stability

0.001 Abs/h (700 nm, one hour after light source)

Baseline Flatness

<0.001 Abs rms (200 to 1,100 nm, after one hour warm-up)

Stray Light

< 0.05% (at 220 nm with 0.1% Nal)

<0.05% (at 340 nm with 0.5% NaNO2)

RMS noise

< 0.0002 Abs rms (at 700 nm)

Monochromator

Czerny-Turner Monochromator

Standard Cell Holder

Multi-cell Holder (8 cells)

Lamp Interchange Wavelength

340 to 410 nm (Default 370 nm)

Operating System (OS)

Android 

Display

7-inch Color Touchscreen LCD (Resolution: 1280 x 800)

Dimensions

433 (W) 381 (D) * 180 (H) mm

Power Requirement

AC 100-240V, 50/60Hz, 140VA

Weight

10.5kg

PC Software
OPTIVIEW for Windows (optional)

※ The contents of this document may be changed without notice.

Optima Inc.

OPTIMA Bldg. 1-6-8 Yamatocho, Nakano-ku, Tokyo 165-0034 JAPAN

TEL : +81-3-5356-9372  |  FAX : +81-3-5356-9373  |  E-mail : optima[at]optima-japan.jp (Replace [at] to @.)

Copyright © OPTIMA Inc. 

ISO9001 Certified